JBC CD-2BQF thermal deviation. Tip C245-944.

Описание к видео JBC CD-2BQF thermal deviation. Tip C245-944.

There is some thermal resistance between the solder tip and the thermocouple, so don't mind the initial 20° temperature difference between what's displayed on the soldering station vs. what's measured by the multimeter. The interesting thing is that the soldering station pretends to stay stable at the set temperature of 350°C, while a wet sponge cools down the tip by more than 40°C. Note that the sponge never touches the thermocouple; only the tip. Apparently the soldering station is programmed to lie about it's own temperature to appear more stable than it actually is.
For full review, see https://retronics.no/2024/09/15/revie...