Logo video2dn
  • Сохранить видео с ютуба
  • Категории
    • Музыка
    • Кино и Анимация
    • Автомобили
    • Животные
    • Спорт
    • Путешествия
    • Игры
    • Люди и Блоги
    • Юмор
    • Развлечения
    • Новости и Политика
    • Howto и Стиль
    • Diy своими руками
    • Образование
    • Наука и Технологии
    • Некоммерческие Организации
  • О сайте

Скачать или смотреть Case 106: PCI Manual - Tortuosity troubleshooting

  • Manos Brilakis
  • 2021-01-29
  • 5035
Case 106: PCI Manual - Tortuosity troubleshooting
PCIpercutaneous coronary interventiontortuositytroubleshootingguide extensionachoring techniqueOrsiro
  • ok logo

Скачать Case 106: PCI Manual - Tortuosity troubleshooting бесплатно в качестве 4к (2к / 1080p)

У нас вы можете скачать бесплатно Case 106: PCI Manual - Tortuosity troubleshooting или посмотреть видео с ютуба в максимальном доступном качестве.

Для скачивания выберите вариант из формы ниже:

  • Информация по загрузке:

Cкачать музыку Case 106: PCI Manual - Tortuosity troubleshooting бесплатно в формате MP3:

Если иконки загрузки не отобразились, ПОЖАЛУЙСТА, НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если у вас возникли трудности с загрузкой, пожалуйста, свяжитесь с нами по контактам, указанным в нижней части страницы.
Спасибо за использование сервиса video2dn.com

Описание к видео Case 106: PCI Manual - Tortuosity troubleshooting

A patient with prior CABG presented with NSTEMI and was found to have severe lesion in a highly tortuous native coronary artery distal to the SVG anastomosis. The SVG was initially engaged with a 6 French Hockeystick guide catheter. The lesion could not be wired with a Sion blue guidewire but was successfully crossed using a Sion black wire. Despite using a Wiggle wire and a 6 French guide catheter extension no balloon (including a Sapphire 1.0 mm balloon) could be delivered through the lesion.
Over the Wiggle wire the guide was changed to a 7 French AL1 guide catheter that provided better support. Using a 6 French guide extension and the Sion black as buddy wire the Sapphire 1.0 mm balloon was delivered to the lesion, but ruptured. A 1.5 and a 2.0 mm balloon could then be delivered to the lesion, followed by delivery of a 2.25x13 mm Orsiro stent that partially covered the lesion. However, a 2nd Orsiro wire could not be delivered until after the Wiggle wire was exchanged for a Grand Slam guidewire. A nice final result was achieved.