Generator Malayalam|DG Malayalam|Cummins|Powerica|Stamford|DG checklist|Electrotech|A Check|unnipgs

Описание к видео Generator Malayalam|DG Malayalam|Cummins|Powerica|Stamford|DG checklist|Electrotech|A Check|unnipgs

#generatorMalayalam #generatormalayalamreview #DGreviewMalayalam
#generatorchecklist
#generatordailyroutinecheck
#electrotech

4 types of dg checklist that every engineer should know

What is preventive maintenance

Preventive maintenance is the process of scheduled checking, replacement of parts, and servicing of a machine to maintain the performance of the machine, increase the efficiency and continue the reliability of the machine.

Why it is important

It is cost-saving

Increase the efficiency of the machine

Reduce the breakdown time of the machine

To Continue the safety of the machine

Diesel generator preventive maintenance dg checklist

There are mainly four types of dg checklist that perform on during preventive maintenance

A check

B check

C check

D check

A check

A check performs daily checking procedure of diesel generator sets.

Check oil level in the diesel generator sets.

Check cleanliness of diesel generator sets.

Check battery voltage

Check for any type of leakage

Check all filter condition

Check coolant level

Check the condition v-belts

B-check-B-check performs on weekly basis or after running hours of (300-350) hours.in this type of check following parameters should be checked:

Change oil

Change oil filter, fuel filter, and bypass filter

Change air filter

Change water separator

Radiator cleaning with chemical

C-check-c-check performed on monthly basis or after running hours of (800-1500) hours

Check all electrical conditions

Check pollution level

Change oil

Change oil filter, fuel filter, and bypass filter

Change air filter

Change water separator

Radiator cleaning with chemical

D-check-D-check performed on yearly basis or after running hours of (3000—5000) hours.

The complete dg set should be dismantled.

turbocharger service

injector pin service

cylinder head service

PT pump service

Change oil

Change oil filter, fuel filter, and bypass filter

Change air filter

Change water separator

Radiator cleaning with chemical


video created by unnipgs electrotech

DG Cummins 380kva
Powerica Stamford sunitha sales and service

topic covered

1. DG maintenance procedure
2. A check
3 B check
4. C check
5. D Check
6 coolant checking
7 oil level checking
8 diesel level checking
9 v belt checking
10 battery voltage checking

Комментарии