Air Pressure testing 1 Pex Loop:
0:00 Recommendation: Pressurize Pex
1:12 Pex Pressure test Procedure 5 Steps
3:25 Test Results & Final Recommendations

Step 1: Crimp off one end of the loop with appropriate size plug.
Step 2: Crimp Pressure Guage Assembly to 2nd end of loop.
Step 3: Over-inflate by 15 - 20 PSI for a period of 30 minutes
Step 4: Top up pressure every 5 - 10 minute during 30 min over-inflation period
Step 5: Drop down to target Test Pressure. Let sit for up to 24 hours.