Easy Viqua VH200 F10 or VH410 F20 UV System Maintenance starts here! Now it’s time for the annual maintenance of replacing the filters and UV lamp. Not sure how or where to start? Well, I’m going to show you how right now!
Before we get started you should know that this exact same procedure applies to both the VH410-F20 and the VH200-F10. Also, be sure not to touch the lamp or the quartz sleeve with your fingers. Handle by ends only or wear soft gloves. Also, if the system has been off for a period of time, or you would like to chemically disinfect your household plumbing, check out this video on disinfection.
VH200-F10 Replacement Bundle here https://waterestore.ca/products/viqua...
VH410-F20 Replacement Bundle here https://waterestore.ca/products/viqua...
1. Shut off water supply and open one down stream faucet to release pressure. Press the button on top of the filter housing to release the pressure from the cartridges.
2. Disconnect power source and allow the unit to cool for about 10 minutes.
3. Remove the lamp connector by squeezing the plastic locking tabs on the side of the connector and pulling.
4. Remove the lamp in upward direction from the chamber and lamp connector base.
5. Remove the bottom and top retaining nut, floating spring from bottom, and O rings. Clean the quartz sleeve with a cloth soaked in CLR, vinegar or some other mild acid and then rinse with water. Note: If sleeve cannot be cleaned completely or it’s scratched or cracked, then replace the sleeve.
6. Reinstall the quartz sleeve in the chamber allowing the sleeve to protrude an equal distance at both ends of the chamber. • Slide supplied O-rings onto each end of the quartz sleeve.
7. Reinstall the top and bottom retaining nuts, floating spring in the bottom, and O-rings.
8. Insert the new lamp fully into the chamber leaving about two inches of the lamp protruding from the chamber.
9. Attach the connector to the lamp. Note that the connector will only allow correct installation in one position
10. Hold down the timer reset button and reapply power to the controller until you see rSET, then release timer reset button. A 5 second delay will occur until you hear an audible tone and LED display will read 365 once again.
11. Remove the filter housing from the unit by turning the blue collar counter-clockwise until it falls free from the head. Pull down the white filter housing (be careful as it will be full of water and will be heavy
12. Remove and discard the old cartridge, wash out the housing and install new cartridge.
13. Reinstall the housing making sure O ring is coated with silicone grease and is fully seated on the housing.
14. Open a faucet downstream of the system and turn on the water supply. After air has been purged, close the downstream faucet. Press the pressure button to purge air.
Easy UV Disinfection Video here    • DISINFECT Your HOUSEHOLD PLUMBING in ...  
To continue to my next video on UV Minirack maintenance click here and I’ll see you there!
UV Minirack playlist.    • Minirack UV  Systems  
LOVE GARY THE WATER GUY AND WANT TO LEARN MORE ABOUT WATER FILTRATION FOR YOUR FAMILY? HERE ARE SOME NEXT STEPS!
1) Sign up to keep in touch with Gary! https://mailchi.mp/waterestore.com/su...

2) LET’S CONNECT!
  / waterestore  
  / waterestore  
  / the-water-filter-estore  
  / water_estore  
  / waterstoremidland  

3) CONTACT!
[email protected] or [email protected]

4) SHOP!
Midland https://www.WaterStoreMidland.com
Canada https://www.WaterEstore.ca
USA https://www.WaterEstore.com

Please share this video    • Easy Viqua VH200 F10 UV System Mainte...  
Please comment or ask questions below. #garythewaterguy #ultravioletdisinfection #waterfiltration

Комментарии

Информация по комментариям в разработке