Invt chf100a IGBT GATE VOLTAGES CHECKING || P.OFF FAULT || igbt change

Описание к видео Invt chf100a IGBT GATE VOLTAGES CHECKING || P.OFF FAULT || igbt change

Invt chf100a igbt gate voltages checking
P.Off fault
Igbt changes
In this video, I discuss the repair of an inverter from invt that was experiencing a P.off error and had a shorted IGBT. The issue was caused by water entering the unit, which cut the lines and affected the voltage generation. I explain the troubleshooting process, including checking the resistor values and voltages at various points, and demonstrate the steps taken to fix the problem. The goal is to provide a detailed guide on resolving this type of issue, as there are not many such videos available on YouTube.
#inverter #IGBTrepair #PFerror #waterDamage #voltageIssues