Скачать или смотреть Liebert GTX4 UPS - Battery Replacement, New Fans and Deep Clean (yes, for 90 minutes)

  • ScottDotDot
  • 2026-01-23
  • 71
Liebert GTX4 UPS - Battery Replacement, New Fans and Deep Clean (yes, for 90 minutes)
uninterruptible power suppliesups battery backupups battery replacementemerson liebertgxt4uninterruptible power supply data centeruninterruptible power supply repairups repairups battery maintenanceuninterruptible power supplyelectricalbattery backupliebert upsemerson upsemerson ups repairbackup power supplyliebertstandby upsups batteries
  • ok logo

Скачать Liebert GTX4 UPS - Battery Replacement, New Fans and Deep Clean (yes, for 90 minutes) бесплатно в качестве 4к (2к / 1080p)

У нас вы можете скачать бесплатно Liebert GTX4 UPS - Battery Replacement, New Fans and Deep Clean (yes, for 90 minutes) или посмотреть видео с ютуба в максимальном доступном качестве.

Для скачивания выберите вариант из формы ниже:

  • Информация по загрузке:

Cкачать музыку Liebert GTX4 UPS - Battery Replacement, New Fans and Deep Clean (yes, for 90 minutes) бесплатно в формате MP3:

Если иконки загрузки не отобразились, ПОЖАЛУЙСТА, НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если у вас возникли трудности с загрузкой, пожалуйста, свяжитесь с нами по контактам, указанным в нижней части страницы.
Спасибо за использование сервиса video2dn.com

Описание к видео Liebert GTX4 UPS - Battery Replacement, New Fans and Deep Clean (yes, for 90 minutes)

I've had two Emerson Liebert GXT4 120V 3kVA UPS units (GXT4-3000RT120) running a bunch of stuff in my basement for going on 10 years now. They've had a few battery replacements in that time, but never a good clean. Hence their disgustingly dusty state. So here I am giving them a decently good clean, and replacing the old fans just in case.

The major problem here was of my own making; I'd ordered replacement batteries quite a while ago and never got around to actually installing them. The SLA batteries sat on a shelf for months and eventually ran down to like 9V and were probably sulfated. Trickle charging them did not save the day, so I went with a new set.

Related videos:
   • New Batteries for a 3000VA APC UPS - Batte...  
   • Automatic Transfer Switches!  (Feat. Serve...  
   • Liebert GXT4 UPS Menu System Walk-Through ...  

00:00:00 Intro
00:07:22 Double Online Conversion and Generators
00:11:09 Powering it on After ~6 Months
00:15:18 Replacing the Batteries
00:34:30 An Unfortunate State of Affairs
00:35:49 Trickle Charging the Bad Batts
00:41:23 Testing the Trickle Charged Batts
00:47:44 Opening the UPS
01:07:10 Cleaning the UPSes
01:13:46 Replacing the Fans
01:20:32 ATS Tangent
01:25:52 Testing the UPSes
01:27:51 Corroded Battery Terminals
01:30:19 Outro and Installed UPSes