HVACR Service Call: Refrigerant Leak Repair/Dual Pressure Control Installation (Refrigeration Unit)

Описание к видео HVACR Service Call: Refrigerant Leak Repair/Dual Pressure Control Installation (Refrigeration Unit)

HVACR Service Call: Refrigerant Leak Repair/Ranco Dual Pressure Control Installation (Commercial Refrigeration Unit Leaking Refrigerant)

Fieldpiece SVG3 Digital Vacuum Gauge
https://amzn.to/3JPM1YO

Yellow Jacket 42004 Series 41 Manifold
https://amzn.to/3dcmWct​

JB Industries DV-6E Eliminator 6 CFM Vacuum Pump
https://amzn.to/3f2CSOh

TurboTorch Kit X-4B (A/C & Refrigeration kit)
https://amzn.to/3b1QZ2R

Diversitech Heat Resistant Cloth 18x18 (Flame Barrier Drop Cloth)
https://amzn.to/2xlFAME

Diversitech Heat Resistant Cloth 18x18 (Flame Barrier Drop Cloth)
https://amzn.to/2xlFAME

Spark Lighter W/5 Extra Flints For Lighting Torch
https://amzn.to/3eo3cRA

Big Blu Micro Leak Detector
https://amzn.to/3t87ndO

Milwaukee 2351-20 M12 LED Stick Light
https://amzn.to/3rVJKEK

Milwaukee M12 2-Tool Combo Kit 2598-22
https://amzn.to/3CtCRNC

Milwaukee Cut 1 Dipped GLOVES L
https://amzn.to/3s8H18O​

Ranco dual pressure controls are used for either operating or protecting commercial refrigeration and air conditioning systems. Within one NEMA 1 enclosure, they are a combination of both high and low pressure controls interconnected to operate a common switch.

Ranco dual pressure controls are suitable for R12(R134a), R22 and R502 refrigerants and are available with either male flare or capillary with flare nut pressure connections.

The O12 series, with a single pole, single throw switch (SPST), will directly control a single phase compressor; the O12 may also be used with a contactor for pilot control for single and three-phase compressors. The O22, with a double pole, single throw switch (DPST), will directly control single of three-phase compressors. The electrical ratings inside the control cover must not be exceeded.

The low pressure closes (cuts-in) the switch on rise of compressor suction pressure and opens (cuts-out) the switch on pressure drop. The high pressure function overrides to open the switch as the compressor discharge pressure rises.

Specifications:
Low Pressure (Open Low): 10" to 100 PSI, 10 PSI fixed differential, manual reset.
High Pressure (Open High): 150 to 450PSI, 70 PSI fixed differential, manual reset.
Capillary: 36" with 1/4" SAE flare nut.
Switch: SPST
FLA: 24Amps @ 120VAC/240VAC

How to install a Ranco dual pressure control
How to install a Ranco dual pressure switch
Commercial refrigeration refrigerant leak repair