Correcting SPT N values to Hammer Energy and Overburden Pressure | Formulas and Procedure

Описание к видео Correcting SPT N values to Hammer Energy and Overburden Pressure | Formulas and Procedure

Standard penetration test (SPT) is widely used field method to estimate the strength of soil. It gives the number of blows (N) to penetrate 15 cm of soil. However, due to the variability of equipment and depths at which this test is performed, some corrections to the hammer energy (assumed 60% energy) and overburden pressure (stress of about 100 kPa) are necessary. This video describes the procedure and use a real-life example to explain how it works in practice. To learn how to use the normalized blow counts to estimate the liquefaction potential of sand, watch this video    • How to Estimate Cyclic Stress Ratio a...  
Related and useful videos: How To Read Borehole Logs    • How To Read Borehole Logs | What You ...  
Pocket penetrometer test    • Pocket Penetrometer Test | What Engin...  
Vane shear test    • Vane Shear Test #education #experiment  
Dynamic cone penetrometer test    • Dynamic Cone Penetrometer Test I Expe...  
Dynamic Cone Penetration Test Analysis    • Dynamic Cone Penetration Test Analysi...  
Schmidt hammer test    • Schmidt Hammer Test | Testing Procedu...  