Logo video2dn
  • Сохранить видео с ютуба
  • Категории
    • Музыка
    • Кино и Анимация
    • Автомобили
    • Животные
    • Спорт
    • Путешествия
    • Игры
    • Люди и Блоги
    • Юмор
    • Развлечения
    • Новости и Политика
    • Howto и Стиль
    • Diy своими руками
    • Образование
    • Наука и Технологии
    • Некоммерческие Организации
  • О сайте

Скачать или смотреть Bifurcation Analysis to Identify Voltage Collapse in Bangladesh Power System

  • Md Khurram Monir Rabby
  • 2025-12-28
  • 1
Bifurcation Analysis to Identify Voltage Collapse in Bangladesh Power System
  • ok logo

Скачать Bifurcation Analysis to Identify Voltage Collapse in Bangladesh Power System бесплатно в качестве 4к (2к / 1080p)

У нас вы можете скачать бесплатно Bifurcation Analysis to Identify Voltage Collapse in Bangladesh Power System или посмотреть видео с ютуба в максимальном доступном качестве.

Для скачивания выберите вариант из формы ниже:

  • Информация по загрузке:

Cкачать музыку Bifurcation Analysis to Identify Voltage Collapse in Bangladesh Power System бесплатно в формате MP3:

Если иконки загрузки не отобразились, ПОЖАЛУЙСТА, НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если у вас возникли трудности с загрузкой, пожалуйста, свяжитесь с нами по контактам, указанным в нижней части страницы.
Спасибо за использование сервиса video2dn.com

Описание к видео Bifurcation Analysis to Identify Voltage Collapse in Bangladesh Power System

The complexity of voltage collapse problem has increased with increasing interconnections between independent power systems. When a bulk power transmission network (generation and transmission system) is operated close to the voltage stability limit, it becomes difficult to control the reactive power demand for that system. As a result, the system voltage stability is affected, which if undetected may lead to voltage collapse. Voltage collapse is generally caused by either of the two types of system disturbances: load variations and contingencies. In respect to voltage collapse phenomenon, information based on loading capability is highly important for the secure operation of the power system. In this paper, the most probable voltage collapse points of the Bangladesh Power System Network (BPSN) have been predicted using continuation power flow method. Voltage stability of BPSN is improved by placing static VAR compensator (SVC). A load flow analysis based technique is used to determine the amount of reactive power support needed. Results show good improvements.

Paper Link: https://ieeexplore.ieee.org/abstract/...
Citation/Reference: M. K. M. Rabby, A. H. Chowdhury, M. A. Azamand and M. A. Towfiq, "Bifurcation analysis to identify voltage collapse in bangladesh power system," 2013 International Conference on Informatics, Electronics and Vision (ICIEV), Dhaka, Bangladesh, 2013, pp. 1-5, doi: 10.1109/ICIEV.2013.6572615.

Комментарии

Информация по комментариям в разработке

Похожие видео

  • О нас
  • Контакты
  • Отказ от ответственности - Disclaimer
  • Условия использования сайта - TOS
  • Политика конфиденциальности

video2dn Copyright © 2023 - 2025

Контакты для правообладателей [email protected]