Скачать или смотреть Sewer Line Inspection Report for: 16266 Sigman St, Hacienda Heights, CA 91745

  • Reliable Property Inspection
  • 2025-12-17
  • 2
Sewer Line Inspection Report for:  16266 Sigman St, Hacienda Heights, CA 91745
  • ok logo

Скачать Sewer Line Inspection Report for: 16266 Sigman St, Hacienda Heights, CA 91745 бесплатно в качестве 4к (2к / 1080p)

У нас вы можете скачать бесплатно Sewer Line Inspection Report for: 16266 Sigman St, Hacienda Heights, CA 91745 или посмотреть видео с ютуба в максимальном доступном качестве.

Для скачивания выберите вариант из формы ниже:

  • Информация по загрузке:

Cкачать музыку Sewer Line Inspection Report for: 16266 Sigman St, Hacienda Heights, CA 91745 бесплатно в формате MP3:

Если иконки загрузки не отобразились, ПОЖАЛУЙСТА, НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если у вас возникли трудности с загрузкой, пожалуйста, свяжитесь с нами по контактам, указанным в нижней части страницы.
Спасибо за использование сервиса video2dn.com

Описание к видео Sewer Line Inspection Report for: 16266 Sigman St, Hacienda Heights, CA 91745

Material Type: The sewer lateral was observed to consist of ABS and clay. It should be noted that other material types may be present but could not be conclusively identified at the time of inspection.

ABS piping is a type of plastic pipe made from acrylonitrile butadiene styrene (ABS) resin. It's often black in color and is used for drainage, waste, and vent (DWV) systems.

Clay sewer piping, also known as vitrified clay pipe (VCP) or terra cotta sewer pipes, are pipes made from a blend of clay and shale, fired at high temperatures to create a hard, inert ceramic material, commonly used in gravity sewer collection mains for their durability and resistance to chemicals in wastewater.

No main line cleanout was located at the time of inspection; therefore, access to the main sewer lateral was obtained via a 4-inch vent stack located on the roof. From the vent stack to approximately 20 feet, the sewer lateral consisted of ABS piping, at which point it transitioned to clay piping continuing to the municipal sewer connection.

Inspection access through a roof vent is considered limited. Roof-mounted vent access does not allow for full cleaning of the line, proper use of locating equipment, or verification of pipe condition at the vent connection, offsets, or transitions. As such, observations are limited to the portions of the sewer lateral that were accessible at the time of inspection, and additional defects may exist that were not visible due to access constraints.
Installation of a code-compliant main line cleanout is recommended in the future to allow for proper access, maintenance, and evaluation of the sewer lateral.

Water distribution was observed to flow smoothly throughout the inspection, with no functional deficiencies or visible defects identified at the time of testing. Conditions are subject to change, and this observation does not guarantee future performance
For ongoing maintenance and peace of mind, it is generally recommended to have your sewer lateral inspected annually, even if no issues are currently present. Regular inspections can help identify and address potential problems before they become costly repairs.