TSP #41 - Teardown and Repair of an Agilent E4433B ESG-D 4.0GHz Synthesized Signal Generator (2014)

Описание к видео TSP #41 - Teardown and Repair of an Agilent E4433B ESG-D 4.0GHz Synthesized Signal Generator (2014)

In this episode Shahriar repairs an Agilent E4433B ESG-D Synthesized Signal Generator. This 4GHz unit shows the "UNLEVEL" error for all frequencies and at all output power levels. After a close look at the system block diagram the fault is traced to the main Output RF board.

The Output RF board is equipped with various amplifiers, electronic attenuators, I/Q mixers, heterodyne paths and final PA. By using soldered SMA cables to various points in the signal path, the fault is traced to an internal amplifier chain which is likely made of a MESFET or JFET transistor. Since this part is obsolete, an RFMD GaAs hybrid amplifier is used in its place. The biasing network and matching networks need to be modified to accommodate this change. The repaired unit is then verified for functionality and performance by measuring a QAM constellation output signal.

The Signal Path Blog
http://www.TheSignalPath.com

Комментарии

Информация по комментариям в разработке