How to solve! Toner Control Fault error reset Xerox Wc 5955 Concentration sensor error 393-360 Part1

Описание к видео How to solve! Toner Control Fault error reset Xerox Wc 5955 Concentration sensor error 393-360 Part1

Hi Friends
Welcome to EXACT MFD INFO !!
Toner Concentration Sensor Failure RAP

393-360-00 - The toner concentration sensor registered a reading outside the expected range.

393-361-00 - TONER LOW
The toner concentration sensor was reading high. This indicates that the toner concentration (TC) was low. Sensor Voltage - more then 2.5v or 3.3v

393-362-00 – TONER HIGH
The toner concentration sensor was reading low. This indicates that the toner concentration (TC) was high. Sensor Voltage - less then 0.9v or 0v

393-364-00
The toner concentration sensor registered a reading outside the range.

Join this channel to get access to perks:
   / @exactmfdinfo  

Kyocera 1800 SPECIFICATIONS -    • Low Budjet KYOCERA I 1800 | 2201 I SP...  
Kyocera 3212i ID COPY -    • HOW TO COPY LENGTH AADHAR CARD | RATI...  
Windows 10 Restart -    • How to solve ?  Windows 10 Your PC ru...  
Xerox 5955 Specification -    • Hi Speed Low Budjut Xerox 5955 Full s...  
Xerox Color 7835 Specification -    • Color Xerox Machine WC 7835,7845,7855...  

EXACT MFD PVT LTD
21, Mettukuppam Main Rd, Chinna Mettukuppam, Maduravoyal, Chennai, Tamil Nadu 600095
PH:- 8189997838
https://goo.gl/maps/ieT1ccnKvNU6vz7U6
https://goo.gl/maps/6HaiWG75e7SZkhas5

  / exactmfdinfo  
  / exactmfdinfo  

#best #tamil #solution #xerox #chennai