Скачать или смотреть Sustained Overvoltage due to Zero Sequence Resonance for Shunt Compensated Transmission Lines

  • EMTP
  • 2024-09-24
  • 155
Sustained Overvoltage due to Zero Sequence Resonance for Shunt Compensated Transmission Lines
  • ok logo

Скачать Sustained Overvoltage due to Zero Sequence Resonance for Shunt Compensated Transmission Lines бесплатно в качестве 4к (2к / 1080p)

У нас вы можете скачать бесплатно Sustained Overvoltage due to Zero Sequence Resonance for Shunt Compensated Transmission Lines или посмотреть видео с ютуба в максимальном доступном качестве.

Для скачивания выберите вариант из формы ниже:

  • Информация по загрузке:

Cкачать музыку Sustained Overvoltage due to Zero Sequence Resonance for Shunt Compensated Transmission Lines бесплатно в формате MP3:

Если иконки загрузки не отобразились, ПОЖАЛУЙСТА, НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если у вас возникли трудности с загрузкой, пожалуйста, свяжитесь с нами по контактам, указанным в нижней части страницы.
Спасибо за использование сервиса video2dn.com

Описание к видео Sustained Overvoltage due to Zero Sequence Resonance for Shunt Compensated Transmission Lines

Shunt compensation reactors, deployed in long AC transmission lines, serve to mitigate overvoltages induced by capacitive charging under light load conditions. However, these reactors can introduce operational challenges, notably sustained overvoltages due to zero sequence resonance. Such resonance occurs in unbalanced conditions, often stemming from circuit breaker malfunctions that result in one- or two-phase disconnections. The zero-sequence resonance is triggered between shunt reactors and phase capacitance in disconnected phases. The overvoltage caused by this resonance can lead to equipment damage.                           
The presentation will cover:

Zero Sequence Resonance: Background on the phenomenon and resulting sustained overvoltages.Case Study: A practical example from a large US wind project.EMTP Simulations: Investigating zero sequence resonance in shunt compensated lines using EMTP® software.Mitigation Measures: Strategies to address the issue, including neutral grounding reactors and specialized protection schemes.

Author: Muhammad Humayan
Company: EnerNex

If you need more information : www.emtp.com