The AC infinity controller 69 finally addresses variable fan speeds to optimize efficiency when cooling and providing co2 to your grow tent. It is imperative for you to understand airflow and VPD to maximize yield and knowing how to use this controller will make a huge difference in yield and overall plant health. In this video, I teach you the settings I use and the reasons why I do what I do. We will teach you how to setup and program your controller using the Bluetooth app for the best settings far plants.

AC Infinity CLOUDLINE T6: https://amzn.to/3xnmguN
AC Infinity CLOUDLINE T4: https://amzn.to/3x1SvxW
AC Infinity Controller 67: https://amzn.to/3xl1wUj

For Veg (Weeks 1 – 6 approx)
Off Fan Speed (Minimum) = 0
On Fan Speed (Maximum) = 5
Max Temp = 78 Fahrenheit 26 Degrees Celsius
Min Temp = Off
Max Humidity = Off
Min Humidity = Off
Transition Temperature = 2 Degrees Fahrenheit or 1 Degrees Celsius

For Transition to Bloom (Weeks 6-8 Approximately)
Off Fan Speed (Minimum) = 1
On Fan Speed (Maximum) = 7
Max Temp 78 Fahrenheit 26 Degrees Celsius
Min Temp = Off
Max Humidity = Off
Min Humidity = Off
Transition Temperature = 2 Degrees Fahrenheit or 1 Degrees Celsius

For Mid - Late Bloom (Weeks 9 and On Approximately)
Off Fan Speed (Minimum) = 2
On Fan Speed (Maximum) = 9
Max Temp 78 Fahrenheit 26 Degrees Celsius
Min Temp = Off
Max Humidity = Off
Min Humidity = Off
Transition Temperature = 2 Degrees Fahrenheit or 1 Degrees Celsius