How To Configure External Alarms on Huawei BBU5900 | External Alarm Configuration on Huawei BTS

Описание к видео How To Configure External Alarms on Huawei BBU5900 | External Alarm Configuration on Huawei BTS

In this video, we discuss How To Configure External Alarms on Huawei BBU5900 | External Alarm Configuration on Huawei BTS
#huawei
#huawei_bts
#AdnanFarooq

Run the SET ALMPORT command to set the alarm ID and port number to be modified.
SET ALMPORT: CN=0, SRN=0, SN=18, PN=0, SW=ON, AID=65083, PT=BOOL, AVOL=HIGH;

Run the SET ENVALMPARA command to set the associated external alarm parameters. The parameters are used to modify the alarm name, alarm severity, and NMS type of the environment alarm.
SET ENVALMPARA: ALMID=65083, ANM="INTRUSION", ALVL=MAJOR, ASS=ENV;

Run the LST ALMPORT command to query the port status of the slot where the external alarm access board is located.

Alarm Name Alarm ID
Door Open 65101
High Temp 32 65102
High Temp 40 65103
AC1 65104
AC2 65105
DC Power Fail 65106
Major Rect. 65107
Minor Rect. 65108
Mains Failure 65109
Low Battery Volt. 65110
Fire Frightening 65111