It's NOT SWA Cable Feeding Your House Cutout Fuse

Описание к видео It's NOT SWA Cable Feeding Your House Cutout Fuse

What is the cable supplying your 100, 80 or 60 amp cutout fuse in a domestic property?
Concentric and split concentric cable explained - aluminium line conductor and a copper combined neutral and earth conductor in concentric cable. The split concentric cable has and aluminium line conductor and copper neutral and copper earth insulated from each other. We see how a concentric cable can be mistaken for a SWA (steel wire armour) cable coming into the bottom of a domestic cutout.

TN-C-S TN-S
T = Terre N = Neutral C = Combined S = Separate

🕕 Time Stamps - Cut to the action 🕕

00:00 - Concentric cable is feeding your cutout
00:30 - Intake equipment
00:59 - Fuse sizes
01:31 - Electric meter
01:45 - Meter seals
03:00 - Concentric cable
03:07 - Aluminium line conductor
03:15 - Copper neutral earth
03:49 - Pulling the cutout fuse
04:37 - Cutout connections
05:03 - TN-C-S
05:42 - Connection on the meter
06:26 - Split concentric cable TN-S

Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2, 3 plus AM2, AM2S and AM2E.