Скачать или смотреть Example 2 - Why Rotation Speed Can Mislead Torque Measurements on Screw and Helix Piles.

  • Pilar ApS
  • 2025-11-16
  • 14
Example 2 - Why Rotation Speed Can Mislead Torque Measurements on Screw and Helix Piles.
torquescrewpilehelixpilehelicalpileadvancement ratioscrewpile installation
  • ok logo

Скачать Example 2 - Why Rotation Speed Can Mislead Torque Measurements on Screw and Helix Piles. бесплатно в качестве 4к (2к / 1080p)

У нас вы можете скачать бесплатно Example 2 - Why Rotation Speed Can Mislead Torque Measurements on Screw and Helix Piles. или посмотреть видео с ютуба в максимальном доступном качестве.

Для скачивания выберите вариант из формы ниже:

  • Информация по загрузке:

Cкачать музыку Example 2 - Why Rotation Speed Can Mislead Torque Measurements on Screw and Helix Piles. бесплатно в формате MP3:

Если иконки загрузки не отобразились, ПОЖАЛУЙСТА, НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если у вас возникли трудности с загрузкой, пожалуйста, свяжитесь с нами по контактам, указанным в нижней части страницы.
Спасибо за использование сервиса video2dn.com

Описание к видео Example 2 - Why Rotation Speed Can Mislead Torque Measurements on Screw and Helix Piles.

In this video, we show why rotation speed during installation is a critical parameter to measure – even though it has no influence on the final bearing capacity of a screw pile.

🔹 Higher rotation speed produces significantly higher torque readings
from 2100 Nm at 5 RPM to 3800 Nm at 80 RPM.
🔹 But the bearing capacity stays the same – only the numbers change.
🔹 Without measuring rotation speed, torque data can create a false sense of security.

Research from Aalborg University clearly demonstrates that torque alone cannot be used as proof of bearing capacity.
To document screw piles correctly, you must also know the advancement ratio and the other installation parameters.

This is exactly why Pilar has developed a system that ensures correct documentation – fast, reliable and fully digital.

📖 Read Aalborg University’s recommendations here:
https://vbn.aau.dk/en/publications/kr...

#ScrewPiles #HelicalPiles #TorqueMonitoring #GreenFoundations #Documentation #SustainableConstruction #Pilar