Tracer gas leak detection investigation on a heating system, losing pressure every 12 hours!

Описание к видео Tracer gas leak detection investigation on a heating system, losing pressure every 12 hours!

Watch as we use tracer gas leak detection to locate a hidden central heating leak.

The central heating system boiler is losing all of its pressure in 12 hours or less.
A boiler engineer has identified a leak on the central heating system.
The boiler has been isolated from the central heating system.
Our engineer has drained all of the water from the central heating pipes.
The central heating system pipes are pressurised with Tracer gases.
The pipes are buried in screed under the flooring.
Traces of the tracer gas were detected behind the washing machine.
Removing the washing machine reveals damp flooring and skirting board.
The sound of a water leak can be heard behind the plasterboard.
Cutting the plasterboard away reveals a leaking pipe fitting in the all.

Once a repair was made a pressure test confirms the system is holding pressure.
ADI Leak Detection specialise in leak detection services.

Find out more at https://www.adileakdetection.co.uk

Central Heating Leak Detection -
https://www.adileakdetection.co.uk/ce...

Tracer Gas Leak detection - https://www.adileakdetection.co.uk/tr...
Call now for a quote on 0800 731 3843 - Lets get it!