Using Handheld XRF Analyzer H500B to test alloy and mineral samples

Описание к видео Using Handheld XRF Analyzer H500B to test alloy and mineral samples

H500B-Handheld XRF Handheld Material Analyzer
Using Handheld XRF Analyzer H500B to test alloy and mineral samples
www.esi-xrf.com
[email protected]
Your handheld XRF Analyzer for material composition analysis
Instant, on-site ore exploration, mine mapping, excavation, and grade control
Soil Screening; environmental soil testing, determination of toxic elements and pollutants
Non-destructive alloy element analysis with fast, simple reporting and certificate generation
Robust industrial design for nearly any weather condition, field environment


Background
X-ray fluorescence (XRF) spectroscopy is a well-established and commonly used technique in obtaining elemental composition data on solid, powders and liquid samples.

Features:
Improved light elements (Mg, Al, Si, P, S, Cl) analysis performance, low limits of detection
Strong software with standard-less fundamental parameters (FP) algorithm, or use its empirical calibrations when results traceability and superior accuracy are needed
Extremely easy to use with Point-and-Shoot for sample analysis
Minimal sample preparation required
Light weight and compact design that can work at harsh environment
Advanced data management system with flexible multiple data transport methods including USB cable connection, storage card, Wi-Fi and Bluetooth.
Extensive, Editable grade library for accurate alloy identification
Can be used as a bench-top unit when ordered with table stand accessory

Technical specifications
Analytical Method Energy Dispersive X-ray fluorescence
PDA with Touch screen CPU: 2G, System memory: 8G
Intelligent Analysis Automatic select test mode based on sample matrix
Excitation Source 50KV/200µA – Ag/Rh/W end window integrated miniature X-ray tube and high voltage power supply
Collimator & Filter Multiple Collimator and filters with automatic switching functions
Detector High Resolution Silicon Drift Detector
Sample States Solids, liquids, powders
Detection Limit 5– 500ppm, depending on element and sample matrix
Analysis Time 3-60 seconds
Simultaneous Analysis Displays up to 40 elements at a time
Display Range ppm – 99.99%
Safety Automatic shutdown of X-ray tube, Pb-lined instrument frame,radiation levels within international safety standards
Power Supply Rechargeable Li battery, standard 6800mAh, provides up to 12 hours operation on a single charge; 110/220V universal adapter for charging
Temperature -20ºC to +50ºC
Size 235 mm x 82 mm x 260 mm
Weight Instrument without battery : 1 . 35 kg,Instrument with battery: 1 . 49 kg

Typical Applications:
Base-line soil surveys
Waste effluent monitoring
Derelict mine investigations /Contaminated land assessment/Hazardous and toxic metals in soil
Site remediation and validation
Mineral mining Grade control
Geo-chemical mapping
Mineral Environmental compliance
Lead/Zinc/Copper – exploration/mining/processing
Nickel laterite and sulphide – exploration/mining/processing
Minerals sands – exploration/mining/processing
Uranium and Thorium - exploration/mining/processing
Pathfinders for precious metals – exploration
Iron ore, bauxite and coal exploration/mining/processing
Silver and rare earth metals exploration/mining/processing

Extended application include:
Fast Non-destructive Positive Material Identification (PMI)
Scrap Metal Sorting and Verifying
Alloy Grade Verification
Chlorine & RoHS: Cr, Hg, Pb, Br and Cd compliance
Analysis of Pt, Pd and Rh in catalytic converters
Analysis of lube oils

Комментарии

Информация по комментариям в разработке