Trigger cycled timer control board simplified.

Описание к видео Trigger cycled timer control board simplified.

Mode selection screen: Long press the "SET" key to enter, after setting is completed, long press the "SET" key to exit back to the main screen.

Operating mode:

P1: trigger signal, the relay is on "OP" time, and then disconnect; in the "OP" time, as follows:
P1.1: signal is triggered again, invalid.
P1.2: signal is triggered again, the clock is reset
P1.3: Signal trigger again, relay off, stop the clock.
P-2: trigger signal, the relay off "CL" of time, the relay on "OP" time, and then disconnect relay;
P3.1: trigger signal, the relay is turned on after the "OP" time, the relay off "CL" time, then the operation cycle, if the trigger signal period, the relay off, stop the clock; the number of cycles ( "LOP ") can be set.
P3.2: without triggering signal, the relay is on "OP" time, the relay off "CL" time, and has been cycling; frequency ( "LOP") cycle can be set.
P-4: signal holding function. If there is a trigger signal timing is cleared, the relay remains on; when the signal disappears, after the timing "OP" time, the relay is; if another signal during timing, timing is cleared.

After setting the mode selection screen parameter value by a short press "STOP" button to select the time range.
XXX. decimal point in the unit place, time range: 1 second to 999 seconds.
X decimal point in decade place, Timing range: 0.1 seconds to 99.9 seconds
X. X. decimal full brightness, Timing range: 1 minute to 999 minutes.
For example, you want to set "OP" is 3.2 seconds, then move the decimal point to decade place, the digital display 03.2
Parameter description: "OP" - conduction time, "CL" - off time, "LOP" - the number of cycles (1-999 times, "---" represents infinite loop).
Product parameters: