SWEEP FREQUENCY RESPONSE ANALYZE TEST, SFRA TEST FOR TRANSFORMER, FULL CONCEPT, TEST RESULT ANALYZE

Описание к видео SWEEP FREQUENCY RESPONSE ANALYZE TEST, SFRA TEST FOR TRANSFORMER, FULL CONCEPT, TEST RESULT ANALYZE

00:00 WEL COME
00:03 PRINCIPLE & PURPOSE OF SFRA
00:59 CONCEPT OF RLC
01:43 RLC IN TRANSFORMER
02:11 RLC ROLE IN TRANSFORMER
02:45 RLC WORKING PRINCIPLE
03:40 TEST KIT TYPES
03:52 TEST KIT ACCESSORIES
04:05 TEST PROCEDURE WITH GENERAL CIRCUIT
04:56 TEST CONNECTION PROCEDURE FOR HV
06:02 TYPES OF TEST CONNECTION FOR TWO WINDING TR
06:33 TYPES OF TEST CONNECTION FOR THREE WINDING TR
07:34 TEST CONNECTION FOR LV
07:59 FREQUENCY RANGES
08:58 SFRA TEST RESULT ANALYZE
09:31 TEST RESULT TYPES ANALYZE
10: 07 THANK YOU

FINGER PRINT TEST

BUS BAR DIFFERENTIAL TEST | 87B TEST | BUS BAR STABILITY TEST | SWITCHGEAR TEST | SITE ACTUAL TEST
   • BUS BAR DIFFERENTIAL TEST | 87B TEST ...  

CT TESTING, CURRENT TRANSFORMER TESTING WITH CT ANALYZER, PRACTICLE TESTING, TEST REPORT MAKING EASY
   • CT TESTING, CURRENT TRANSFORMER TESTI...  

CT TESTING, MULTI RATIO CURRENT TRANSFORMER TESTING WITH CT ANALYZER & CT SB2.SITE PRACTICAL TESTING
   • CT TESTING, MULTI RATIO CURRENT TRANS...  

ATS-AUTOMATIC TRANSFER SWITCH IN SWITCHGEAR FULL EXPLANATION, ATS SITE TEST, AUTO TRANSFER SWITCH
   • ATS-AUTOMATIC TRANSFER SWITCH IN SWIT...  

SWEEP FREQUENCY RESPONSE ANALYZE TEST, SFRA TEST FOR TRANSFORMER, FULL CONCEPT, TEST RESULT ANALYZE
   • SWEEP FREQUENCY RESPONSE ANALYZE TEST...  

TRANSFORMER TAN DELTA TEST, POWER FACTOR TEST, FULL CONCEPT, MODES GST, UST, TYPES, PURPOSE, PART -1
   • TRANSFORMER TAN DELTA TEST , POWER FA...  

TRANSFORMER TAN DELTA TEST, DISSIPATION FACTOR TEST, POWER FACTOR TEST, GSTg, TEST REPORT, PART - 2
   • TRANSFORMER TAN DELTA TEST, DISSIPATI...  

TURNS RATIO TEST - ENGLISH, CIRCUIT DIAGRAM, TEST REPORT ANALYSE, FORMULA, RATIO TEST OF TRANSFORMER
   • TURNS RATIO TEST - ENGLISH, CIRCUIT D...  

Dyn1 VECTOR GROUP TEST, POWER TRANSFORMER TESTING, தமிழ் ,SITE PRATICAL TEST, RESULT ANALYZE
   • Dyn1 VECTOR GROUP TEST, POWER TRANSFO...  

TRANSFORMER MAGNETIC BALANCE TEST OR CORE BALANCE TEST தமிழ், SITE TEST, EASY UNDERSTANDING
   • TRANSFORMER MAGNETIC BALANCE TEST OR ...  

AMMETER TESTING BY SECONDARY INJECTION, தமிழ் ,CPC 100, CT RATIO 800/5, CROMPTON AC AMMETER TESTING
   • AMMETER TESTING BY SECONDARY INJECTIO...  

ACB TESTING, AIR CIRCUIT BREAKER LONG, SHORT DELAY TRIP, INSTANTNAEOUS TRIP, GROUND FAULT, SITE TEST
   • ACB TESTING, AIR CIRCUIT BREAKER LONG...  

VOLTMETER TESTING BY SECONDARY INJECTION, தமிழ், SITE TEST, CPC100, VT RATIO, AC VOLTMETER TESTING
   • VOLTMETER TESTING BY SECONDARY INJECT...  

Комментарии

Информация по комментариям в разработке