Anti Surge Control System Design as per API 670- Scan Time Requirement of Controller

Описание к видео Anti Surge Control System Design as per API 670- Scan Time Requirement of Controller

Anti Surge Control System Design as per API 670- Scan Time Requirement of Controller;
API 670 is a standard published by the American Petroleum Institute (API) that provides recommendations for the design and maintenance of anti-surge control systems for centrifugal compressors. The standard covers both mechanical and electronic anti-surge control systems and applies to compressors used in the oil and gas industry. Some of the key design considerations for anti-surge control systems as per API 670 include:

The design of the anti-surge control system should be based on the compressor performance characteristics, including the surge line, compressor map, and operating limits.

The anti-surge control system should be able to accurately detect and measure the variables that are critical to the operation of the compressor, such as flow, pressure, and temperature.

The anti-surge control system should be able to respond quickly and accurately to changes in operating conditions to prevent surge.

The anti-surge control system should be designed with appropriate safety margins to ensure reliable operation and prevent compressor damage.

The anti-surge control system should be designed to be maintainable and easy to troubleshoot, with clear documentation and diagnostic information.

The anti-surge control system should be designed to minimize the risk of failure and minimize the impact of any failures that do occur.

The anti-surge control system should be designed to be compatible with the overall control system of the plant and should not interfere with the operation of other equipment.

The anti-surge control system should be designed to be robust and reliable, with appropriate redundancy and backup systems in place to ensure continuous operation.

The anti-surge control system should be designed to be flexible and adaptable, with the ability to accommodate changes in operating conditions or upgrades to the compressor or control system.

The anti-surge control system should be designed to be energy efficient, with the goal of minimizing energy consumption while maintaining reliable operation.

The anti-surge control system should be designed to be easy to commission and start up, with clear procedures and guidelines for testing and verifying the system's performance.

The anti-surge control system should be designed to meet all relevant safety and environmental regulations and standards.


Regenerate response

Комментарии

Информация по комментариям в разработке