Centurion D5 evo- motor fault, move and stop, no limits available.

Описание к видео Centurion D5 evo- motor fault, move and stop, no limits available.

Centurion D5 Evo gate motor, moves with bumps, does not accept limits, move and retreat, battery, control board, magnetic, DOSS cable and sensor, all ok.
Possible problem, oil leaking into the rotor compartment – the oil blocking the reader holes will result in miscounting the travel distance of the gate – Note, in some cases it will do a limit setup with no problem but running it will cause stopping to short, not stopping at all or give false obstruction statuses.
Solution:
Remove the 4 screws in order to open the rotor compartment, Clean the disc so that it is completely unlocked.
Put new rubber rings if you have, to avoid oil going to DOSS sensor compartment .
Good luck.
----------------------------------------------------------------------------------------------------------------------------
Motor de portão Centurion D5 Evo, move com solavancos, não aceita limites, move e recua, bateria, placa de controle, magnético, cabo DOSS e sensor, tudo ok.
Possível problema, vazamento de óleo no compartimento do rotor – o óleo bloqueando os orifícios do leitor resultará na contagem incorreta da distância de deslocamento do portão – Observe, em alguns casos, ele fará uma configuração de limite sem problemas, mas ao executá-lo causará uma parada curta, não parar de jeito nenhum ou dar falsos status de obstrução.
Solução:
Remova os 4 parafusos para abrir o compartimento do rotor, Limpe o disco para que fique completamente destravado.
Coloque novos anéis de borracha se tiver, para evitar que o óleo vá para o compartimento do sensor DOSS.
Boa sorte.