PCIe 5 and the Road to PAM4 Anritsu GRL Webinar

Описание к видео PCIe 5 and the Road to PAM4 Anritsu GRL Webinar

Type-D 'Phase Localized'는 고정 장치가 사용되는 주파수 범위를 기반으로 전기적으로 충분히 길다는 가정과 함께 사용되는 단일 표준(라인 또는 반사/반사 쌍)을 의미하고 고정 장치 불일치의 대부분을 증명합니다. 내부 평면에 너무 가깝지 않습니다. 이 데모에서는 길이가 0인 선이 표준으로 선택되었습니다. 고정물 반쪽 사이의 대칭은 삽입 손실로 알려져 있습니다. 단일 전송 라인을 2로 나누려고 하기 때문에 일치가 완벽하다고 가정합니다.

"Type-D ‘Phase Localized’ implies a single standard (either a line or a reflect/reflect pair) being used along with the assumption that the fixture is electrically long enough based on the frequency range being used and proving the bulk of the fixture mismatch is not too close to the inner plane. In this demonstration, a zero length line was chosen as the standard. The symmetry between the fixture halves is known for the insertion loss. The match is presumed to be perfect since we try to divide a single transmission line by two, representing a two halves fixture.
Instructions:
Make sure the appropriate 2-port calibration is active.
Zero out match terms if desired. This sets all reflection terms to 0 and may be helpful if the fixture is extremely unrepeatable.
Select the measurement type (using thru). Set the magnitude thru line to 1 which means 0 dB loss and the length is zero.
Enter an estimate of the network's electrical delay. Entering 0 will activate the automatic length estimator.
Enter the file names and path where the output .s2p files will be stored. The Quick Extract option can be used instead: time stamped files will be saved to a predetermined hard disk location and the de-embedding engine will automatically load those files. Remember to keep track of available disk space.
When all fields have been entered and proper connection of the standard(s) has/have been made, click on 'Perform Network Extraction'. If successful, files will automatically be saved and a confirmation dialog will appear.
If Quick Extract was not selected, after the .s2p files have been saved, go to Measurement/Edit Embed/De-embed/Edit Network configuration panel to recall the .s2p files and configure the network.
Go to embedding/de-embedding menu, select port 1.
Add .s2p file (the one generated by the port 1 in Type-D), click on Add Network, click Apply.
Add .s2p file (the one generated by port 2 in Type-D), click on Add Network, click Apply.
Turn on the de-embed, a 0 dB insertion loss is observed from the trace S12.