Well Water Storage Tank System With Bypass

Описание к видео Well Water Storage Tank System With Bypass

This is a brief overview on building an automatic well water storage tank system including a bypass to return to the standard submersible pump to pressure tank system.
Parts used:
Float switches (2):
SJE Pumpmaster #SJE 1002737
normally closed/on (when pointing down per video)

Relays:
Relay for tank "top off" float switch (runs submersible pump)
Rheem sku 42-25102-01
Normally open/off relay for filling storage tank when tank level is low.

Normally closed/on relay for "tank empty" float switch. Cut out/ protection for jet pump
Square D # CA2KN22B7
Normally Closed relay for jet pump protection.

Transformer:
Rheem sku SP10550B
120 volts AC to 24 volts AC. (This transformer powers float switches to activate relays)

Surface/Jet Pump
Franklin "versajet" #91180007 3/4 horse pump (switchable to 120 or 240 volt)
After 2 years of use I give this pump 5 stars.

Pressure gauge:
Any brand with 1/4" threads
Check valve: Any brand that fits your pipe size. Brass ones are generally better quality.