Start Up of my first Solar System, after Hurricane Maria

Описание к видео Start Up of my first Solar System, after Hurricane Maria

This is the first start up of my solar system, after Puerto Rico was hit by Hurricane Maria. I know this is not an ideal setup, but there was a shortage of materials, so bear with me.

The system is composed of a Schneider SW 2524 Inverter, a Schneider MPPT 60 150 Charge Controller and the Schneider Conext-SCP.

The energy was stored in 16 Absorbent Glass Mat battery's, each of them where 12 volts @ 42.5 amp-hours connected in 8 parallel strings, each having 2 battery's in series for a total of 24 volts @ 340 amp-hours equal to 8160 watts-hours.

At the roof there where 6 solar panels, each rated at 260 watts for a total of 1560 watts. The configuration was 2 strings in parallel, each having 3 solar panels in series, for a maximum Voltage Open Circuit of 90 volts @ 18 amps.