Timer relay module motor wiring and setting
Product parameters:
1: Working voltage: 6-30V support micro USB 5.0V power supply
2: Trigger signal source: high-level trigger (3.0V-24V) The signal ground and the system ground are not in the same ground to improve the anti-interference ability of the system (also can be short-circuited to the common ground)
3: Output capability: can control equipment within DC 30v 5A or AC 220v5A
4: Quiescent current: 20mA working current: 50mA
5: Service life: more than 100,000 times; working temperature: -40—85°C; size: 6.2*3.8*1.7cm
6: With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit board, set parameters will be remembered forever after power failure.


Special attention: The relay output is a passive contact, uncharged output, and controls the on-off function of a line.



Module Highlights:

1. Wide voltage power supply (6~30V) supports micro USB 5.0V power supply, which is very convenient to use;
2. The interface is clear and simple, powerful, easy to understand, and almost meets all your needs;
3. There is a key emergency stop function (STOP key), with reverse connection protection, reverse connection does not burn;
4. Different OP, CL, LOP parameters can be set, these parameters are independent of each other and saved separately;
5. All set parameters are automatically saved after power-off.



Operating mode:
P1: After the signal is triggered, the relay is turned on for OP time, and then turned off; during OP time, the following operations
P1.1: The signal is invalid when triggered again
P1.2: The signal is triggered again to re-timing
P1.3: The signal triggers the reset again, the relay is disconnected, and the timing stops;


P-2: Give the trigger signal, after the relay is turned off for CL time, the relay is turned on for OP time, after the timing is completed, the relay is turned off;


P3.1: Give the trigger signal, after the relay is turned on for the OP time, the relay will disconnect for the CL time, and then cycle the above actions, give the signal again in the cycle, the relay will disconnect, and stop timing; the number of cycles (LOP) can be set;
P3.2: There is no need to trigger signal after power-on, the OP time of relay is on, the CL time of relay is off, the above actions are cycled; the number of cycles (LOP) can be set;


P-4: Signal holding function. If there is a trigger signal, the timer is cleared and the relay remains on; when the signal disappears, the relay is disconnected after timing the OP; during the timing, there is another signal, and the timer is cleared;


How to set timing on timer in incubator.this timer use in incubator to controll the timning of rolling trays and turning trays.
#Timer_for_incubator
#Vehla_Munda
how to set timer
how to set timer for incubator
incubator timer, timer setting
timer setting incubator
digital timer setting
digital timer for incubator
egg incubator
timer for incubator
incubator settings for chicken eggs
incubator setting temperature
how to make timer for incubator
timer for egg incubator
best timer
how to
how to set timer for lights
timer switch control
timer settings
how to connect digital timer switch
Incubator egg turning daley setting and wiring in urdu
Automatic egg incubator
Egg turning daley timer setting and wiring

Комментарии

Информация по комментариям в разработке