Logo video2dn
  • Сохранить видео с ютуба
  • Категории
    • Музыка
    • Кино и Анимация
    • Автомобили
    • Животные
    • Спорт
    • Путешествия
    • Игры
    • Люди и Блоги
    • Юмор
    • Развлечения
    • Новости и Политика
    • Howto и Стиль
    • Diy своими руками
    • Образование
    • Наука и Технологии
    • Некоммерческие Организации
  • О сайте

Скачать или смотреть Control Valve Calibration with 4–20 mA Signal | Stroke Test & Hysteresis | BDG10503 Instrumentation

  • KidWho
  • 2025-06-27
  • 116
Control Valve Calibration with 4–20 mA Signal | Stroke Test & Hysteresis | BDG10503 Instrumentation
  • ok logo

Скачать Control Valve Calibration with 4–20 mA Signal | Stroke Test & Hysteresis | BDG10503 Instrumentation бесплатно в качестве 4к (2к / 1080p)

У нас вы можете скачать бесплатно Control Valve Calibration with 4–20 mA Signal | Stroke Test & Hysteresis | BDG10503 Instrumentation или посмотреть видео с ютуба в максимальном доступном качестве.

Для скачивания выберите вариант из формы ниже:

  • Информация по загрузке:

Cкачать музыку Control Valve Calibration with 4–20 mA Signal | Stroke Test & Hysteresis | BDG10503 Instrumentation бесплатно в формате MP3:

Если иконки загрузки не отобразились, ПОЖАЛУЙСТА, НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если у вас возникли трудности с загрузкой, пожалуйста, свяжитесь с нами по контактам, указанным в нижней части страницы.
Спасибо за использование сервиса video2dn.com

Описание к видео Control Valve Calibration with 4–20 mA Signal | Stroke Test & Hysteresis | BDG10503 Instrumentation

🔧 BDG10503 Instrumentation – Control Valve Experiment

In this video, we demonstrate how a control valve responds to varying electrical input signals (4–20 mA) and measure the corresponding valve stroke length. This experiment focuses on observing the linear response and identifying hysteresis behavior during valve opening and closing cycles.

📍 What’s Inside:

🧪 Experiment Objectives:

Understand the configuration and working principle of a control valve system

Develop and test a functioning circuit for control valve operation

Measure stroke lengths at different current levels and analyze system performance

🛠️ Equipment Used:

Control Valve

VFD Control Panel

I/P Transducer

⚙️ Procedure Highlights:

Signal sent from 4 mA to 20 mA and back down

Stroke length measured at 0%, 25%, 50%, 75%, and 100%

Comparison of rising and falling stroke values to identify hysteresis

Safety protocols followed strictly throughout the testing process

📊 Key Observations:

The valve shows a nearly linear response during opening

Slight hysteresis observed on the closing cycle

Importance of calibration highlighted for maintaining control accuracy

🎯 Conclusion:
This experiment successfully demonstrates how control valves behave under different current inputs, reinforcing the importance of calibration and maintenance in industrial flow control systems.

Presented by Group 1, Section 1
#ControlValve #Instrumentation #BDG10503 #ValveCalibration #EngineeringLab #Hysteresis #ProcessControl

Комментарии

Информация по комментариям в разработке

Похожие видео

  • О нас
  • Контакты
  • Отказ от ответственности - Disclaimer
  • Условия использования сайта - TOS
  • Политика конфиденциальности

video2dn Copyright © 2023 - 2025

Контакты для правообладателей [email protected]