Karcher Window Vac | Green light stays on fault | WV2

Описание к видео Karcher Window Vac | Green light stays on fault | WV2

Thanks to ‪@CatherineHendry-t6e‬ for pointing out in a previous video that the green light on the switch, is supposed to turn off.

Original video:    • This is why your Karcher WV2 Window V...  

Knowing this, I couldn't resist the urge to take a second look at the WV2 and dig deeper into this less known fault.

00:00 Explaining the green light problem
01:05 Opening the Karcher Window Vac T9 torx bit
03:00 Removing 3.7v battery and DC motor
04:00 Testing the circuit board for shorts and voltages
06:48 Examining the switch and LED enclosure
08:50 LED, transistor, microcontroller circuit explained
11:00 Removing microcontroller from circuit. Lifting pin 8
12:39 Checking the NPN transistor for faults
14:00 Replacing SMD BCR108 SOT23 NPN transistor
15:00 Testing the board with the new transistor
15:55 Original battery fitted and tested
16:45 DC Motor installed tested
17:05 Assembling the Karcher WV2 window vac
19:20 Final test is successful

Another mention to user Harox from the Discord server Learn Electronics Repair for his support, confirming my suspicions and finding the correct replacement.

If you like the video please hit the thumbs up button.

Support me by liking the video and please consider subscribing

Support me on Patreon:   / philipbryden  

Tools:
Multimeter: AstroAI Digital Multimeter, TRMS 6000
Soldering Iron: KSGER T12 Soldering Station
Hot air station: Quick 857DW+
Bench PSU: Tenma 72-2540 30V 5A
Digital Oscilloscope: Rigol DS1054Z
Desolder pump: Duratool

Microsoldering set up:    • Micro soldering set up | Microscope s...  

Disclaimer:
The information provided in this video is for entertainment use only.
I am not a professional and any methods I use might not be the correct ones.
I will not accept any responsibility for loss, damage or injury as a result of the information provided in this video.