Configuring Danfoss VLT AutomationDrive FC 360 for CRANE (CROSS TRAVEL) || DIGICON AUTOMATION

Описание к видео Configuring Danfoss VLT AutomationDrive FC 360 for CRANE (CROSS TRAVEL) || DIGICON AUTOMATION

Configuring Danfoss VLT AutomationDrive FC 360 for CRANE (CROSS TRAVEL) Application || DIGICON AUTOMATION

Parameters :

1-01 MOTOR CONTROL PRINCIPAL [1] VVC+
1-20 MOTOR kW ONE VALUE HIGHER THEN MOTOR kW
1-22 MOTOR VOLTAGE AS PER MOTOR NAME PLATE
1-23 MOTOR FREQUENCY AS PER MOTOR NAME PLATE
1-24 MOTOR CURRENT AS PER MOTOR NAME PLATE
1-25 MOTOR RPM AS PER MOTOR NAME PLATE
1-60 LOW SPEED LOAD COMPENSATION 180%
2-10 BRAKE FUNCTION [1] RESISTOR BRAKE
2-11 BRAKE RESISTOR (ohm) *
2-12 BRAKE POWER LIMIT (kW) *
2-20 RELEASE BRAKE CURRENT 30% OF MOTOR CURRENT
2-22 ACTIVATE BRAKE SPEED [Hz] 10 Hz
3-10 [0] MAIN SPEED REFERENCE 100%
3-15 REFERENCE RESOURCE 1 0
3-16 REFERENCE RESOURCE 2 0
3-17 REFERENCE RESOURCE 3 0
3-41 ACCELERATION TIME *
3-42 DECELERATION TIME *
4-14 MOTOR SPEED HIGH LIMIT 50 Hz
4-16 TORQUE LIMIT MOTOR MODE MAXIMUM
5-10 TERMINAL 18 DIGITAL INPUT [8] START
5-11 TERMINAL 19 DIGITAL INPUT [11] START REVERSE
5-12 TERMINAL 27 DIGITAL INPUT NO OPERATION
5-13 TERMINAL 29 DIGITAL INPUT NO OPERATION
5-14 TERMINAL 32 DIGITAL INPUT NO OPERATION
5-15 TERMINAL 33 DIGITAL INPUT NO OPERATION
5-16 TERMINAL 31 DIGITAL INPUT NO OPERATION
5-40 FUNCTION RELAY [32] MECHANICAL BRAKE CTRL

* As per product value or as per application

Комментарии

Информация по комментариям в разработке